Siemens ACUSON S2000

Siemens Healthineers · ACUSON series

Cart-basedObstetrics & GynecologyVascularMusculoskeletal

Siemens ACUSON S2000 cart-based ultrasound system

The Siemens ACUSON S2000 is an ultrasound system designed with a focus on general imaging and women's health, cleared for abdominal, OB/GYN, vascular, musculoskeletal and other applications. In its family it sits between the entry-level S1000 and the premium S3000. It offers Virtual Touch elastography, and an Automated Breast Volume Scanner (ABVS) configuration adds automated 3D breast imaging.

Released
2007first FDA clearance
Probe ports
3plus a continuous-wave port
Display
21.5-inchLCD on HELX Evolution units
Weight
max. 170 kgwith documentation devices

Compatible probes

Linear

  • 9L4 · 4–9 MHz Multi-D matrix
  • 14L5 · 5–14 MHz Multi-D matrix
  • 14L5 SP · 5–14 MHz Sterilizable; intraoperative
  • 18L6 HD · 5.5–18 MHz

Convex & microconvex

  • 4C1 · 1–4.5 MHz
  • 6C1 HD · 1.5–6 MHz
  • 6C2 · 2–6 MHz
  • 7CF2 · 2–7 MHz Volume (mechanical 3D)
  • 8C3 HD

Phased

  • 4P1 · 1–4.5 MHz Multi-D matrix
  • 4V1 · 1–4.5 MHz
  • 4V1c · 1–4.5 MHz
  • 8V3 · 2.5–8 MHz
  • 10V4 · 4–10 MHz

Endocavity

  • EC9-4 · 3.75–9 MHz
  • EV-8C4 · 4–9 MHz Endovaginal
  • 9EVF4 · 4–9 MHz Endovaginal volume
  • MC9-4 Endovaginal

Specialty

  • V5Ms · 3–7 MHz Multiplane TEE
  • V7M · 4–8 MHz Pediatric and adult TEE
  • AcuNav 8F · 4–10 MHz Intracardiac catheter; needs the cardiac package
  • AcuNav 10F · 4–10 MHz Intracardiac catheter; needs the cardiac package
  • CW2 Continuous-wave Doppler, 2 MHz
  • CW5 Continuous-wave Doppler, 5 MHz
  • 14L5BV For the ABVS configuration

Specifications

Display
Monitor
21.5-inch LCD (HELX Evolution); LED-backlit, 1080p on HELX Evolution with Touch Control
Touch screen
12.1-inch (30.7 cm) high-resolution touch display with Instant Response technology
Physical
Weight
Max. 170 kg with documentation devices; approx. 137 kg (303 lbs), Touch Control familyShow all
Dimensions
623 mm wide, 1,103 mm deep, 1,330–1,630 mm high (systems with a touch screen)
Transducer ports
Three array-transducer ports and a separate continuous-wave port
Controls
Laser-optical trackball, digital and tactile keyboards, mode-sensitive backlightingShow all
Gel warmer
Integrated, with customizable positions
Power & battery
Energy consumption
0.03 kW in standby; 0.57 kW average during patient examination
Battery
Mobile QuikStart: installed battery holds standby for approximately four hours unplugged
Power-off time
60 seconds from operating state to off-mode
Connectivity & options
DICOM
Verification, Storage, Storage Commitment, Query/Retrieve, Worklist, MPPS, PrintShow all
Network
IEEE 802.3 Ethernet, 10 Base-T and 100 Base-T; DICOM on port 104 (VE10)
Wireless DICOM
Optional wireless DICOM reporting; data transfer to PowerScribe 360
Removable media
CD-R and DVD-R (DICOM media, VE10)
ABVS configuration
Automated Breast Volume Scanner (ABVS): automated 3D and hand-held breast imaging
Quantitative Ultrasound (QUS)
License-controlled option at VE11A; with Ultrasonically-Derived Fat Fraction (UDFF)
Imaging & software
Imaging modes
B, M, PW and CW Doppler, Color and Amplitude Doppler, harmonic imaging, 3D/4DShow all
Revision and software
Classic (VC25 or below), HELX Evolution (VC30A), HELX Evolution with Touch ControlShow all
Operating system
Windows 7
Architecture
SieStream HD signal processing (HELX Evolution with Touch Control)
Image optimization
eSieImage multiparametric optimization, frame by frame and hands-free
Image enhancement
Advanced SieClear, Clarify VE, SieScape panoramic imaging, Native tissue harmonic imagingShow all
Elastography
ARFI-based Virtual Touch imaging, quantification and IQ; eSie Touch elasticity imagingShow all
Contrast imaging
CEUS with Cadence Contrast Harmonic Imaging (CHI) and Contrast Pulse Sequencing (CPS)
3D/4D imaging
3-Scape real-time 3D; fourSight 4D; STIC fetal heart imaging; Amnioscopic rendering
Measurement packages
syngo Auto OB and Auto Left heart, Velocity Vector Imaging, Arterial Health PackageShow all
Workflow
eSieScan protocols on the touch display; Smart-swap annotations; body markersShow all
Multi-modality review
Available on HELX Evolution with Touch Control
Environment
Operating environment
10–40 °C room temperature; 10–80% relative humidity in the examination room
Noise level
48 dB(A) at basic load; 50 dB(A) at full load, measured to NEMA
Cooling
Air-cooled
Compliance
FDA 510(k)
K202683 (2020-10-15), K183575 (2019-03-20), K172162 (2017-08-16) … K072786 (2007-11-13)Show all

What to check when buying a used Siemens ACUSON S2000

  1. Inspect the power cable and its strain relief

    S2000 power cables have split at the IEC connector, frayed from being moved while plugged in or knocked against a wall, and pulled out of the strain relief in transport, leaving a severed wire exposed.

    How: Look along the cord and at both connector ends for fraying, splits or bare wire, and have any frayed cable swapped for a new one before use.

  2. Look for fluid ingress at seams and slots

    Fluid that seeps through the control-panel seams, the keyboard or the DVD slot can reach the circuitry and cause excessive electrical leakage or system failure.

    How: Look around those openings for signs of spilled fluid, and ask which cleaners and disinfectants were used, since products outside the Instructions for Use can damage surfaces and create electrical hazards.

  3. Check biopsy guides against recall Z-2344-2015

    When the 18L6 HD or 6C1 HD biopsy guidelines are used with third-party biopsy attachments, the needle could travel outside the guidelines shown on screen.

    How: If biopsy guides or the S2000 Biopsy Starter Kit come with the unit, match their identifiers against the recall and ask for its correction records.

  4. Check V5M TEE recalls on early software

    On software VA10 through VA16A with cardiac options, the V5M's thermal safety guards did not take effect on its next use if it stayed connected after an automatic thermal shutdown.

    How: Read the software version and ask for the correction records for recalls Z-1392-2011 and Z-1884-2011, the second of which left CW mode inoperative during TEE exams at VA15, VA15A and VA15B.

Common questions about the Siemens ACUSON S2000

Is the Siemens ACUSON S2000 FDA-cleared?

Yes. The S2000 was first cleared under 510(k) K072786, decided on November 13, 2007. Later clearances include K172162, decided on August 16, 2017, for the S1000, S2000 and S3000 at software VE10A, and K183575, decided on March 20, 2019, for the S2000 and S3000 at software VE11A with the Quantitative Ultrasound application. K202683, decided on October 15, 2020, includes the S1000, S2000 and S3000 among several ACUSON platforms.

What is the Siemens ACUSON S2000 cleared to scan?

Under 510(k) K082142, decided on November 13, 2008, the S2000 is cleared for fetal, abdominal, intraoperative, pediatric, small parts, transcranial, OB/GYN, cardiac, pelvic, neonatal and adult cephalic, vascular, musculoskeletal, superficial musculoskeletal and peripheral vascular applications.

How does the ACUSON S2000 differ from the S1000 and S3000?

The S1000 is the entry-level system, focused on vascular and shared-services imaging; it does not support Virtual Touch quantification (VTQ) and is not configured for Quantitative Ultrasound. The S2000 is an all-purpose general-imaging system specializing in women's health. The S3000 is Siemens' premium system, and eSieFusion imaging and eSieGuide needle tracking belong to it rather than to the S2000.

Does Siemens still support the ACUSON S2000?

No. The ACUSON S Family, the S1000, S2000 and S3000, is on Siemens Healthineers' list of end-of-support systems, with the ACUSON Sequoia or ACUSON Redwood as the upgrade path.

Does the ACUSON S2000 support Quantitative Ultrasound (QUS)?

Only at software VE11A, and only when the license-controlled QUS application has been purchased; the VE11A update applies to the S2000 and S3000, not the S1000. Its Ultrasonically-Derived Fat Fraction (UDFF) software was cleared with it under K183575, decided on March 20, 2019.

Is there an ABVS version of the ACUSON S2000?

Yes. The ACUSON S2000 Automated Breast Volume Scanner (ABVS) configuration adds automated 3D breast imaging to hand-held scanning, and it works with hand-held transducers such as the 18L6 HD, including for guided needle biopsy. The 14L5BV transducer belongs to the ABVS configuration.