Siemens ACUSON S1000

Siemens Healthineers · ACUSON series

Cart-basedVascular

Siemens ACUSON S1000 cart-based ultrasound system

The Siemens ACUSON S1000 is a cart-based ultrasound system designed for vascular and shared-services imaging. It was built as the entry point to premium technologies such as elastography and contrast-enhanced ultrasound, and it is FDA-cleared under 510(k) K130619 and later clearances. Its siblings are the ACUSON S2000, for general imaging and women's health, and the premium ACUSON S3000.

Compatible probes

Linear

  • 9L4 · 4–9 MHz Multi-D matrix array
  • 12L4 Software VC31X or above
  • 14L5 · 5–14 MHz Multi-D matrix array
  • 14L5 SP · 5–14 MHz Sterilizable, intraoperative
  • 18L6 HD Requires a license

Convex & microconvex

  • 4C1 · 1–4.5 MHz
  • 6C2 · 2–6 MHz
  • MC9-4
  • 7CF1 · 1–7 MHz Volume transducer
  • 7CF2 · 2–7 MHz Volume transducer

Phased

  • 4P1 · 1–4.5 MHz Multi-D matrix array
  • 4V1 · 1–4.5 MHz Vector format
  • 4V1c · 1–4.5 MHz Sector format
  • 8V3 · 2.5–8 MHz Vector format
  • 10V4 · 4–10 MHz Vector format

Endocavity

  • EC9-4 · 3.75–9 MHz
  • EV-8C4 · 4–9 MHz Endovaginal
  • 9EVF4 · 4–9 MHz Endovaginal volume transducer

Specialty

  • V5Ms · 3–7 MHz Multiplane transesophageal
  • V7M · 4–8 MHz Transesophageal
  • AcuNav 8F · 4–10 MHz Intracardiac catheter; cardiac package
  • AcuNav 10F · 4–10 MHz Intracardiac catheter; cardiac package
  • CW2 · 2–2 MHz CW Doppler pencil probe
  • CW5 · 5–5 MHz CW Doppler pencil probe

Specifications

Display
Monitor
21.5-inch full HD 1080p LCD, LED backlit, IPS (HELX Evolution with Touch Control)Show all
Monitor brightness
170 cd/m² default (21.5-inch monitor)
Monitor arm
Articulating, independent of system and control panel; swivel ±80°, locks for transportShow all
Touch panel
12.1-inch (30.7 cm) WXGA LCD, 1280 x 800, 16:10, Instant Response technologyShow all
Physical
Weight
160 kg (353 lbs); 187 kg (412 lbs) fully configured
Width
62.3 cm (24.5 in)
Depth
110.3 cm (43.4 in)
Monitor top height
130 cm (51.2 in) to 156.7 cm (61.7 in)
Control panel height
77.5 cm (30.5 in) to 93 cm (36.5 in) from handle
Minimum fold-down height
125 cm (49.2 in), folded for transport
Control panel
Floating, ±38° swivel, 85–100 cm vertical articulation, tri-color backlightingShow all
Trackball and keyboard
Laser-optical trackball; pull-out keyboard and touch-screen keyboard
Transducer ports
3 universal ports with electronic selection, an Aux CW port and a parking portShow all
Transducer storage
6 transducer cup holders, specialty holders and an optional integrated gel warmerShow all
Power & battery
Power
100 V, 115 V or 230 V (50/60 Hz) versions; maximum 1.2 kVAShow all
Heat output
2400 BTU/hr maximum
QuikStart standby
Startup from standby in approximately 30 s; shutdown to standby in approximately 10 s
Connectivity & options
DICOM
Storage, Print, Query/Retrieve, Worklist, Storage Commitment and structured reportingShow all
Network
Ethernet 10/100/1000-base T (RJ-45); dual-band 2.4/5 GHz 802.11 a/b/g/n wirelessShow all
USB and video
2 USB 2.0 ports at the touch screen, 4 USB ports at the back; HDMI out and in; DVIShow all
Storage and media
2.0 TB hard drive; Blu-ray read, DVD±R and CD-R read/writeShow all
Documentation devices
Up to three (up to two on board): color printer, B/W thermal printer or Blu-ray DVR
Reporting and data transfer
Wireless DICOM reporting, PowerScribe 360 data transfer, VueBox data transfer (options)
Audio
Speakers integrated with the monitor; directional microphone for DVR voice recording
Remote service
Siemens Remote Service (SRS); eSieLink Remote Assistance screen sharingShow all
Imaging & software
Revision and software
Release 1.0, HELX Evolution, HELX Evolution with Touch Control (VD10A and above)Show all
Operating system and security
Windows 7; Siemens Ultrasound System Security (USS) application and change control
Beamforming
Fully digital; up to 67,392 processing channels; SieStream HD architectureShow all
Imaging modes
2D with native THI; M-mode; color Doppler velocity and energy; PW and CW Doppler; 3D/4DShow all
Elastography
eSie Touch elasticity imaging (compression elastography of relative tissue stiffness)
Contrast imaging
Cadence Contrast Harmonic Imaging (CHI) and Contrast Pulse Sequencing (CPS)Show all
Image optimization
eSieImage multiparametric optimization (requires an eSieImage optimization license)
Imaging options
Advanced SieClear, Clarify VE, Dynamic TCE, TEQ, SieScape, 3-Scape, fourSight 4D, DTIShow all
Optional software packages
Fetal Heart STIC, syngo Arterial Health Package, syngo VVI, Multi-modality ReviewShow all
Environment
Ambient temperature
+10 to +40 °C (50–104 °F)
Humidity
10–80%, non-condensing
Atmospheric pressure
700–1060 hPa, or up to 3050 m (10,000 ft)
Fan noise
48–50 dBA maximum
Compliance
FDA 510(k)
K202683, K172162, K163635, K162243, K152369, K142876, K140959, K132804, K130619Show all
Quality system
FDA QSR 21 CFR Part 820; ISO 13485:2003
Design standards
UL 60601-1; CSA C22.2 No. 601.1; EN/IEC 60601-1; EN/IEC 60601-2-37Show all
Acoustic output
IEC 61157; AIUM/NEMA UD-2; AIUM/NEMA UD-3
Languages
Languages
English, French, German, Italian and Spanish (screen, control panel, instructions)Show all

What to check when buying a used Siemens ACUSON S1000

  1. Inspect the power cord and its outlet

    A power cord on an ACUSON S1000 has caught fire, a failure linked to use with a damaged outlet receptacle.

    How: Look along the whole cord for cuts, crushing or scorching, especially where it has been pressed against a wall or bed, retire any cord showing mechanical damage, and ask for a recent electrical safety check.

  2. Check the 18L6 HD biopsy guide alignment

    Under Class 2 recall Z-2344-2015, a needle passed through the 18L6 HD biopsy guide could travel outside the on-screen guidelines.

    How: If the system comes with an 18L6 HD biopsy kit, ask for the record of the recall correction and have Siemens service confirm that the needle path matches the on-screen guidelines.

  3. Check control-panel seams for fluid ingress

    Fluid that seeps into the circuitry can cause excessive leakage current or system failure, and spray cleaners can force it in through the console's openings.

    How: Look for residue or staining around the control-panel seams, the keyboard and the DVD slot, and ask whether spray cleaners were used on the console.

  4. Check the Doppler manual-trace software fix

    On software VC30A, VC30B, VC30C and VC31A, the manual Doppler trace tool in full-screen format could miscalculate Time Average Velocity and with it the Pulsatility Index, the subject of recall Z-2314-2015.

    How: Read the installed software version, and on those releases ask for the service record of the correction, measuring manual traces outside full-screen display until it is installed.

Common questions about the Siemens ACUSON S1000

Is the Siemens ACUSON S1000 FDA-cleared?

Yes. The ACUSON S1000 Diagnostic Ultrasound System was cleared under 510(k) K130619 on March 21, 2013, and later clearances naming it include K132804, K140959, K142876, K152369, K162243, K163635, K172162 and K202683, the last decided on October 15, 2020.

Its cleared indications under K163635 span fetal, abdominal, intraoperative, pediatric, small parts, transcranial, OB/GYN, cardiac, pelvic, neonatal and adult cephalic, vascular, musculoskeletal, superficial musculoskeletal and peripheral vascular applications.

Is the Siemens ACUSON S1000 discontinued?

Yes. The ACUSON S1000 is discontinued, and its commercial distribution ended on December 31, 2021.

How does the Siemens ACUSON S1000 differ from the S2000 and S3000?

The ACUSON S1000 is designed for vascular and shared-services imaging, the ACUSON S2000 for general imaging and women's health, and the ACUSON S3000, the family's premium system, for general imaging and interventional radiology.

Under K163635, eSie Fusion is on the S3000 only, VTI is on the S2000 and S3000 only, and the 6C1 HD and 8C3 HD transducers are cleared for the S2000 and S3000 only.

When did the Siemens ACUSON S1000 come out?

Siemens announced shipment of the ACUSON S1000 on March 12, 2012, and announced the HELX Evolution generation, which includes the S1000, in April 2014.