
The Siemens ACUSON Cypress is a portable cardiovascular ultrasound system for echocardiography and vascular imaging, with transducer technology carried over from the ACUSON Sequoia. It handles adult and pediatric transthoracic echo, multiplane TEE, intracardiac echo with AcuNav catheters, and peripheral and abdominal vascular studies. Its 2006 PLUS release added a 12.1-inch tilting display and home-base controls.
Compatible probes
Linear
- 7L3 Vascular; Cypress CV system
Convex & microconvex
- 4C1 Abdominal vascular; Cypress CV system
Phased
- 3V2c Adult cardiac
- 7V3c Pediatric cardiac
Specialty
- Aux CW 2 MHz non-imaging CW Doppler
- V5Ms Adult multiplane TEE; needs the V5Ms Adapter
- 5.0 MHz Biplane TEE Transesophageal
- 5.0 MHz Monoplane TEE Transesophageal
- ACUSON AcuNav 10F Ultrasound Catheter Intracardiac, 10 French x 90 cm
- ACUSON AcuNav 8F Ultrasound Catheter Intracardiac, 8 French x 110 cm; Cypress CV system
- SOUNDSTAR eco Diagnostic Ultrasound Catheter Intracardiac; connects through a SwiftLink cable
Specifications
Display
- Display (PLUS release)
Integrated digital 12.1-inch (30.7 cm) flat panel with tiltIntegrated digital 12.1-inch (30.7 cm) flat panel display with tilt; integrated design for console or tabletop useShow allShow less
- Display (original system)
- Integrated LCD with color GUI
Physical
- Weight (PLUS release)
- 19 lbs / 8.6 kg
- Weight (original system)
- 8 kg (19 pounds) in 2002; under 20 pounds (under 9 kg) when shipping began in 2000
- Dimensions (PLUS release)
34.7 cm H × 39.6 cm W × 19.4 cm D keyboard up, 43.2 cm D keyboard downHeight 13.67 in (34.7 cm); width 15.58 in (39.6 cm); depth 7.64 in (19.4 cm) with keyboard up, 17.0 in (43.2 cm) with keyboard downShow allShow less
- Controls and user interface
- Fold-up keyboard, dedicated controls, color GUI display and Doppler audio
- Controls (PLUS release)
- Home-base control layout
- Mounting (PLUS release)
- Integrated design for console or tabletop use
- Mobile cart
Optional custom cart: latching mount, height adjustment, 4-wheel pivot, UPSOriginal Cypress: used on a table top or on a custom mobile cart. PLUS release: optional mobile custom cart with integrated mounting platform with latch, 12 in / 30.7 cm height adjustment, 4-wheel pivot, 3 transducer holders, gel holder, shelves for peripherals and storage, Uninterruptible Power Supply (UPS), cable managementShow allShow less
- Transducer connector (PLUS release)
- EC601BF connector type
Power & battery
- Power (PLUS release)
100-120/200-240 V AC, 50-60 Hz, 1.2/0.6 A, 144 VA nominal inputUniversal power supply for North America and international requirements; input voltage 100-120/200-240 V AC; 50-60 Hz; 1.2/0.6 A; nominal input power 144 VAShow allShow less
Connectivity & options
- DICOM (PLUS release)
- DICOM output to PACS and DICOM Modality Worklist; DICOM Network Output option
- Connectivity (original system)
DICOM embedded; studies on internal disk, sent to a network or magneto-optical driveDICOM communications standard embedded; internal disk storage of patient studies; network output; studies transferred in DICOM or native Cypress format to an integrated magneto-optical drive or over a network to DICOM-compliant systemsShow allShow less
- CypressViewer software
- Offline study review and analysis on a PC over the network
- CSV12 Software Viewer
PC accessory reproducing Cypress database, storage, viewing and quantificationPC software accessory reproducing the Cypress patient-database, study-storage, viewing and quantification functionsShow allShow less
- Options (PLUS release)
Integrated Stress Echo, ICE, IMT, Advanced Triggering, DICOM Network Output, Custom CartIntegrated Stress Echo; Intracardiac Echo (ICE); Intima-Media Thickness (IMT) Measurements; Advanced Triggering; DICOM Network Output; Custom CartShow allShow less
Imaging & software
- Clinical applications (PLUS release)
Adult/pediatric TTE, multiplane TEE, ICE (AcuNav), peripheral and abdominal vascularAdult and pediatric transthoracic echocardiography (TTE); multiplane transesophageal echocardiography (TEE); intracardiac echocardiography (ICE) with ACUSON AcuNav ultrasound catheters; peripheral vascular; abdominal vascularShow allShow less
- Imaging modes (PLUS release)
2D (fundamental, harmonic), Color Doppler Velocity and Energy, M-mode, PW/CW Doppler2D fundamental and harmonic imaging; Color Doppler Velocity; Color Doppler Energy; M-mode; PW spectral Doppler; CW spectral Doppler; Duplex with PW and CW DopplerShow allShow less
- Imaging modes (original system)
2D harmonic imaging, M-mode, color Doppler, PW and CW Doppler, contrast agent imaging2D (including harmonic imaging), M-mode, color Doppler, pulsed-wave and continuous-wave Doppler, contrast agent imaging and integrated stress echoShow allShow less
- Measurements and packages
Calculations, report and analysis packages, integrated stress echo, IMT packageComprehensive calculations package and stress echo (2002); on the PLUS release, measurements and calculations with report and analysis packages, including integrated stress echo, and an IMT application packageShow allShow less
- Reporting
Patient report with audio capture; voice annotation; report to inkjet printer or PCPatient report with audio capture; from 2001, studies transferred in a multimedia format viewable on a standard PC, voice annotation of digital study files, and patient reports printed directly to an inkjet printer or sent to a PC in a word-processing-compatible formatShow allShow less
- System architecture
- Fully digital phased array system on a proprietary architecture
- Revision and software
- PLUS release, available from the end of April 2006
Compliance
- FDA 510(k)
K010950 (06/27/2001), K021497 (07/09/2002), K042055 (08/16/2004), K052331 (11/10/2005)K982800 (September 22, 1998), the same system cleared under an earlier device name and marketed as the Cypress; K010950, Cypress System (June 27, 2001); K021497, Cypress Ultrasound System (July 9, 2002); K042055, Cypress Ultrasound System (August 16, 2004); K052331, ACUSON Cypress Ultrasound System (November 10, 2005): Class II, product codes IYN, IYO and ITXShow allShow less
- Safety standards
Designed to conform to CSA C22.2 No. 601-1, the EN 60601-1 family and ISO 10993Designed to conform to CSA C22.2 No. 601-1; AIUM/NEMA UD-2, 1998; AIUM/NEMA UD-3, 1998; 93/42/EEC Medical Device Directive; EN 60601-1; EN 60601-1-1; EN 60601-1-2; EN 60601-1-2-37 (as printed); ISO 10993Show allShow less
What to check when buying a used Siemens ACUSON Cypress
Watch for smoke or sparks at power-up
A Cypress has sparked and smoked when it was switched on, and another began smoking suddenly during an exam and had to be shut down.
How: Power the unit up and run it through an extended scanning session, and reject it at any smoke, sparking or burning smell.
Have a biomed run an electrical safety test
The Cypress was designed to conform to medical electrical safety standards, and with smoke and sparking reported on the system, a used unit has to be shown to still meet them.
How: Have a biomedical engineer run a leakage test to the medical electrical safety standard before the unit touches a patient, and reject it on a fail.
Feel each transducer's lens and connector after scanning
A Cypress transducer has been found hot to the touch at the lens, the face that rests on the patient, and at its connection to the system.
How: After a period of scanning, touch the lens face and the connector of every transducer, and set aside any that is hot at either point.
Check the serial number against both software recalls
Ranges of Cypress units were recalled for a software problem that lost data and for one that kept an imaging mode from appearing on screen, each fixed with a software change.
How: Read the serial plate and compare it with recalls Z-0975-03 and Z-0744-04, and on a listed unit confirm the software fix was applied and every imaging mode shows on screen.
Common questions about the Siemens ACUSON Cypress
Is the Siemens ACUSON Cypress FDA-cleared?
Yes. The Cypress is FDA-cleared through a series of 510(k)s: K010950 (June 27, 2001), K021497 (July 9, 2002), K042055 (August 16, 2004) and K052331 (November 10, 2005), which classes it as a Class II device.
An earlier clearance, K982800 of September 22, 1998, was granted to the same system under another device name, and the system was marketed as the Cypress.
What is the Siemens ACUSON Cypress cleared to scan?
Its 2005 clearance, K052331, is for general imaging and cardiology: fetal, abdominal, intraoperative cardiac, pediatric, neonatal cephalic, adult and pediatric cardiac, transesophageal, peripheral vessel, intraluminal and intracardiac applications.
Does Siemens still support the ACUSON Cypress?
No. Siemens set December 31, 2019 as the end-of-life date for the Cypress, and its service support is unavailable after that date.
When was the Siemens ACUSON Cypress released?
The Cypress began shipping in North America in June 2000. Its PLUS release was announced on March 23, 2006, for availability at the end of April 2006.
Was the ACUSON Cypress Siemens' first portable ultrasound?
It was Siemens' first portable ultrasound machine for echocardiography. Siemens' first portable ultrasound system of any kind was the SONOLINE 1000 of 1982, and its ACUSON P10 of 2007 is a pocket-sized device.