The Mindray Resona I9T is a cart-based ultrasound system for general imaging, vascular, women’s imaging and shared service applications, in the Mindray Private Office line. It pairs a 23.8-inch LED monitor with a 15.6-inch HD touchscreen and a free-floating control panel; an optional battery supports up to two hours of continuous scanning. The Resona I9 is another trade name of the same Resona I9 series system.
- Released
- 2021first FDA clearance
- Display
- 23.8-inchLED monitor
Compatible probes
Linear
- L9-3s
- L12-3RCs
- L14-3Ws
- L16-4Hs
- L20-5s
Convex & microconvex
- C4-1s
- C6-2Gs
- SC6-1s Single crystal
- SC8-2s Single crystal
- C11-3s Micro-convex
Phased
- SP5-1s Single crystal
- P8-2s
Endocavity
- V11-3Hs
- DE11-3Ws Volume
- ELC13-4s Bi-plane
Specialty
- SD8-1s Single crystal volume
- CW2s Continuous wave
- CW5s Continuous wave
Specifications
Display
- Display
- 23.8-inch high-resolution LED monitor, 1920 × 1080
- Touch screen
- 15.6-inch HD touchscreen, 1920 × 1080, customizable and gesture-operated
Physical
- Weight
- 105 kg ± 4 kg (standard configuration)
- Dimensions
L 1020 ± 20 mm, W 550 ± 10 mm, H 1000 ± 20 mm (monitor and control panel at minimum)Length 1020 ± 20 mm; width 550 ± 10 mm; height 1000 ± 20 mm, with the monitor and control panel at their minimum positionShow allShow less
- Controls
iConsole, E-Ink keys, free-floating panel (lifts, swivels), trackball, QWERTY keyboardiConsole control panel with customizable E-Ink keys; fully free-floating control panel that lifts and swivels; trackball; QWERTY keyboardShow allShow less
- Probe ports
- Elevated transducer ports; separate pencil-probe connector on the front I/O panel
- Design
- Modular design for serviceability
Power & battery
- Battery
- Up to two hours of continuous scanning; battery assembly is optional
- Battery pack
Single 14.4 VDC, 6600 mAh battery; no less than 90 minutes of normal workingSingle battery, 14.4 VDC, 6600 mAh; supports normal working for no less than 90 minutes; a fully discharged battery generally charges in less than 6 hours; the battery assembly is an optionShow allShow less
- Power
- 100–240 VAC, 50/60 Hz; 650 VA power consumption; auxiliary AC outlets up to 300 VA
Connectivity & options
- Configuration
- Functions vary with the specific system purchased
- I/O ports
USB 3.0, HDMI 2.1, VGA, S-Video, RJ45, ECG/DC in, PCG in, audio in/out, pencil probeUSB 3.0 Type A; HDMI Type A (HDMI 2.1); VGA output; S-Video output; RJ45 network port; ECG/DC IN; PCG input; audio input and output; pencil probe connectorShow allShow less
- Network
Wired RJ45 10/100/1000 M; Wi-Fi 802.11 ac/a/b/g/n at 2.4G/5G, WPA/WPA2; adapter optionalWired RJ45 Ethernet 10/100/1000 M; Wi-Fi IEEE 802.11 ac/a/b/g/n at 2.4G/5G with WPA/WPA2; the built-in wireless adapter is an optionShow allShow less
- DICOM
Optional DICOM Basic, needed for Worklist, MPPS and Query/Retrieve options; HL7 worklistDICOM Basic (optional), with DICOM Worklist, DICOM MPPS and DICOM Query/Retrieve as options that require it; DICOM structured reports for OB/GYN, Cardiac, Breast, Abdomen, Small Parts, Urology, Pediatric and Vascular; Worklist supports DICOM and HL7Show allShow less
- Hardware options
CW module, 4D/TEE module, ECG module, PCG kit, fusion kit, battery, wireless adapter…Pencil probe cable; CW Module Kit; 4D/TEE module kit; built-in wireless adapter; battery assembly; ECG Module Kit (AHA); PCG Transducer Kit; Ultrasound Fusion Imaging Kit; iClear+ Dongle; iVocal Microphone PackageShow allShow less
- Video printers
- P95DW-N (black/white digital), UP-X898MD (black/white analog), UP-D25MD (digital color)
Imaging & software
- Imaging platform
- ZONE Sonography® Technology+ (ZST+)
- Imaging modes
B, M, PW, CW, Color and Amplitude Doppler, Tissue Harmonic Imaging, Smart3D, 4D, TDI…B, M, PW, CW, Color Doppler and Amplitude Doppler; combined B+M, PW+B, Color+B, Power+B, PW+Color+B and Power+PW+B; Tissue Harmonic Imaging; Smart3D; 4D (real-time 3D); iScape View; TDI; Color M; Strain Elastography; contrast imaging (LVO, liver); V Flow; STE; STQ. Availability depends on configuration.Show allShow less
- Clinical packages
Abdomen/General, Obstetrics, Gynecology, Cardiology, Small Parts, Urology, Vascular…Abdomen/General; Obstetrics; Gynecology; Cardiology; Small Parts; Urology; Vascular; Pediatrics; Nerve; Emergency&Critical; Pelvic FloorShow allShow less
- Sound Speed Compensation (SSC)
- Determines signal speed automatically from detected tissue characteristics
- Ultra-Micro Angiography (UMA)
- Doppler processing that separates tissue motion (clutter) from low-velocity blood flow
- Shear Wave Elastography (SWE)
- High frame rate STE for live 2D shear wave imaging
- Contrast Enhanced Ultrasound (CEUS)
- Second-generation Ultra-Wideband Non-Linear (UWN+) imaging; High Frame Rate CEUS
- Contrast imaging options
Contrast Imaging, Contrast Imaging QA, LVO, Volume CEUS (4D module), HiFR CEUS, TCMR…Contrast Imaging; Contrast Imaging QA; LVO; Volume CEUS (needs the 4D module); HiFR CEUS; CEUS Chrono-Parametric Mode; TCMRShow allShow less
- Elastography options
- Strain Elastography; STE; STQ; Endocavity STE; High frame rate STE
- Liver and flow options
USAT, HRI+, V Flow, Ultra-Micro Angiography, Glazing Flow, iClear+ (dongle required)USAT (UltraSound ATtenuation analysis); HRI+ (HepatoRenal Index Plus); V Flow; Ultra-Micro Angiography; Glazing Flow; iClear+ (needs the iClear+ Dongle)Show allShow less
- 3D/4D options
Smart 3D, iPage+, STIC, SCV+, Color 3D, iLive and others; most need the 4D moduleSmart 3D; iPage+; STIC; SCV+; Smart Volume; Smart V Trace; Color 3D; Niche; iLive; Smart Planes CNS; Smart Planes FH; Tissue-Contrast Mix Rendering; Smart Face; Smart ICV; Smart Scene 3D (most require the 4D module)Show allShow less
- Cardiac options
TDI, TDI QA, Stress Echo, Tissue Tracking QA, FH Tissue Tracking QA, AutoEF, Smart IVC…V Flow; IMT; RIMT; R-VQS; V-Mapping (Vascular Package required); AutoEF (Cardiology Package required)Show allShow less
- Vascular options
V Flow, IMT, RIMT, R-VQS, V-Mapping (Vascular Package required)V Flow; IMT; RIMT; R-VQS; V-Mapping (Vascular Package required); AutoEF is listed in the same table (Cardiology Package required)Show allShow less
- OB/GYN tools
- Smart OB, Smart NT, Smart Fetal HR, Smart FLC, Smart Pelvic, IVF, IOTA
- Fusion and navigation options
- Ultrasound Fusion Imaging, Endocavity Fusion Imaging, Fusion RESP, Needle Navigation
- Other software options
iScape View, Free Xros M, Free Xros CM, Smart Hip, Smart HRI, Smart Bladder…iScape View; Free Xros M; Free Xros CM; Smart Hip; Smart HRI; Smart Bladder; Smart Trace; CPP; Smart B-line; iWorks; iNeedle; DVR Module; antivirus software (Windows systems); ClamAV (Linux systems); iVocal; 3D-Print FormatShow allShow less
- Named technologies
HD Scope, iScape Panoramic View, Bidirectional Power Doppler, Glazing Flow, Dual live…HD Scope; iScape Panoramic View; Bidirectional Power Doppler; Glazing Flow; 4D Automated Assessment of Intracranial Volume (ICV); Automated Ejection Fraction (Auto EF); Dual live; Left Ventricular Opacification (LVO); Tissue Doppler ImagingShow allShow less
- Software updates
- Living Technology™, Mindray's software-based upgrade approach for installed systems
- Operating system
- Windows 10 64-bit or Linux 64-bit
- Processor
- X86, 3.7GHz (minimum hardware configuration)
- Storage
- 128G SSD + 1T HDD, both standard (minimum hardware configuration)
Environment
- Operating environment
- 0–40 °C; 20–85% relative humidity, non-condensing; 700–1060 hPa
Compliance
- FDA 510(k)
- K240684 (2024-06-17), K210699 (2021-06-10); Class II, product codes IYN, IYO, ITX
What to check when buying a used Mindray Resona I9T
Have a biomed run the electrical safety tests
They measure protective earth resistance and earth, enclosure and patient leakage, faults that a visual inspection cannot see.
How: Ask for the safety analyzer results, with the earth leakage test run before the other leakage tests and the mains-on-applied-part test included.
Reject probes with damaged lenses or exposed wiring
A probe with a damaged or scratched surface or exposed wiring must not be used on a patient.
How: Look over each probe head for cracks, swelling, scratches or exposed wiring, and for gel left on the face, whose water can get into the acoustic lens.
Inspect the power cord, plug and adapter
A cracked or loose cord, damaged pins or a plug that runs warm is an electrical hazard.
How: Look for wrinkles, cracks, deterioration or looseness in the cord, cracks or swelling on the adapter surface, broken, bent or discolored plug pins and a damaged strain relief, and confirm the plug does not run warm in use.
Listen and smell for overheating after power-on
Rattles inside the case or a burning smell point to an internal fault.
How: With the system running, listen for rattles inside the case and check the ventilation holes for burning or smoky smells and signs of overheating.
Common questions about the Mindray Resona I9T
Is the Mindray Resona I9T FDA-cleared?
Yes. The Resona I9T is FDA-cleared as a Class II device under product codes IYN, IYO and ITX. It is a listed trade name in 510(k) K240684, decided on June 17, 2024, and in the earlier 510(k) K210699, decided on June 10, 2021; both cover the Resona I9 series Diagnostic Ultrasound System.
What exams is the Mindray Resona I9T cleared for?
Its 510(k) K240684 clears it for adults, pregnant women, pediatric patients and neonates. The cleared exams are fetal, abdominal, intra-operative (abdominal, thoracic and vascular), laparoscopic, pediatric, small organ (breast, thyroid and testes), neonatal and adult cephalic, trans-rectal, trans-vaginal, musculoskeletal (conventional and superficial), thoracic/pleural, adult and pediatric cardiac, trans-esophageal (cardiac), peripheral vessel and urology.
How does the Mindray Resona I9T relate to the Resona I9?
The Resona I9 and the Resona I9T are trade names of one Resona I9 series Diagnostic Ultrasound System in 510(k) K240684. Mindray catalogs the Resona I9 under General Imaging and the Resona I9T under Private Office. Both have a 23.8-inch LED monitor, a 15.6-inch HD touchscreen with a floating control panel, and a battery for up to two hours of continuous scanning.
What warranty does the Mindray Resona I9T come with?
Bought directly from Mindray North America, the Resona I9T comes with five years of coverage for the main system and parts, technical phone support, standard transducers (normal wear and failure) and software performance updates with Living Technology. Specialty transducers, including TEE and 4D transducers, are covered for one year. Terms for a system bought through a Mindray agent can differ.