GE LOGIQ P9 XDclear
GE HealthCare · LOGIQ series

The GE LOGIQ P9 XDclear is a general imaging ultrasound system, used from triage to comprehensive exams in obstetrical, gynecological, vascular, musculoskeletal and cardiac work. On R4 and R4.5 units it has a 23.8-inch monitor and 4 active probe ports, and weighs 67 kg at minimum load. The LOGIQ P10 is the highest P Series configuration, and the LOGIQ P9 and LOGIQ P8 each offer a subset of its features.
- Released
- 2015first version launched
- Probe ports
- 4 active3 RS + 1 DLP, R4/R4.5
- Display
- 23.8-inchLCD monitor, R4/R4.5
- Weight
- 67 kg148 lb, min. load, R4/R4.5
Compatible probes
Linear
- 9L-RS
- 12L-RS
- L3-12-RS
- L3-9i-RS Intraoperative, subject to regional clearance
- L4-12t-RS
- L6-12-RS
- L8-18i-RS
- L10-22-RS
- ML6-15-RS Matrix array
Convex & microconvex
- C1-5-RS
- C1-6-D DLP connector; added with R4
- C2-7-D DLP connector; added with R4
- 8C-RS Microconvex
- 10C-D Microconvex, DLP connector; added with R4
- RAB2-6-RS 4D volume probe
Phased
- 3Sc-RS Cardiac, abdomen, transcranial
- 6S-RS Cardiac, pediatric, neonatal
- 12S-RS Pediatric, neonatal
- M5Sc-RS Added to the P Series with R4
Endocavity
- E8C-RS Transvaginal, transrectal
- E8CS-RS Transvaginal, transrectal
- IC9-RS Transvaginal, transrectal
- BE9CS-RS Transrectal
- RIC5-9A-RS 4D volume; transvaginal, transrectal
Specialty
- 6Tc-RS Transesophageal
- P2D CW pencil
- P6D CW pencil
- P8D CW pencil
Specifications
Display
- Main monitor
- 23.8-inch bezel-less LCD, LED backlight, on an articulating arm (R4, R4.5)
- Touch screen
- 10.4-inch LCD touch screen
- Main monitor (R1–R3)
- 21.5-inch color LCD; 10.4-inch LCD touch screen
- Display modes
- Full-size or split-screen live/stored display; 4×4 review; still and Cine thumbnails
Physical
- Weight
67 kg (148 lb) at minimum load; 83 kg (183 lb) at maximum load (R4)67 kg (148 lb) at minimum load and 83 kg (183 lb) at maximum load on R4; 67 kg (148 lb) on R4.5.Show allShow less
- Weight (R1–R3)
- 60 kg (133 lb)
- Dimensions
H 1,345–1,595 mm with the monitor arm; W 545 mm (monitor); D 740 mm (rear handle)Height 1,345–1,595 mm (53.0–62.8 in) with the articulating monitor arm; width 430 mm (16.9 in) at the keyboard, 495 mm (19.5 in) at the foot cover, 545 mm at the monitor; depth 685 mm (27.0 in) at the foot cover, 740 mm (29.1 in) at the rear handle. The same height, width and 740 mm depth on R4 and R4.5.Show allShow less
- Dimensions (R1–R3)
- Height 1,375–1,570 mm; width 530 mm monitor, 430 mm operator panel; depth 740 mm
- Probe ports
- 4 active: 3 RS and 1 DLP; optional CW pencil probe port (R4, R4.5)
- Probe ports (R1–R3)
- 3 active, 4th active port optional; optional CW pencil probe port
- Controls
Full-size keyboard, swivel and height adjustable; digital TGC and A/N keyboardErgonomic full-size keyboard with swivel and height adjustment; digital TGC and digital A/N keyboard, with a physical A/N keyboard optional; customizable keys, joystick and touch control; articulating monitor arm, with the monitor moving about 150 mm vertically and 250 mm horizontally; operator panel rotating about 30 degrees to each side; programmable foot switch optional.Show allShow less
- Console equipment
Integrated SSD, speakers, probe holders, front handle, probe light; optional DVD drive…Integrated solid state drive, speakers, probe holders, front handle and probe light; on-board storage for a B/W printer; optional integrated DVD multi-drive, gel warmer and rear handle.Show allShow less
Power & battery
- Power
100–240 Vac, 50/60 Hz; maximum 500 VA with peripherals100–240 Vac, 50/60 Hz; power consumption maximum 500 VA with peripherals. By supply: 100–120 VAC ±10% at 5.0–4.1 A or 220–240 VAC ±10% at 2.2–2.0 A, 50/60 Hz (±2%), nominal 500 VA including all on-board peripherals, on a dedicated single branch circuit.Show allShow less
- Battery
Optional Power Assistant, Li-ion; extended battery: up to one hour of offline scanningOptional Power Assistant, a lithium-ion battery or extended battery in the power supply module: the system can be moved without a full shutdown and boot-up, and the extended battery allows battery-powered live (offline) scanning for up to one hour (release not stated).Show allShow less
Connectivity & options
- Connectivity
Ethernet; DICOM 3.0 option; wireless LAN option; InSite ExC; LOGIQ P Apps (Bluetooth)Ethernet network connection; DICOM 3.0 option with Verify, Print, Store, Modality worklist, Storage commitment, Modality Performed Procedure Step (MPPS), Media exchange, Off network/mobile storage queue and Query/retrieve; DICOM directory import; wireless LAN option, subject to regional regulatory clearance; InSite ExC remote capability; LOGIQ P Apps over Bluetooth (option).Show allShow less
- Structured reporting
- Public SR template; vascular and OB structured reporting; direct DICOM SR and XML export
- Inputs and outputs
HDMI, S-video and composite video out; RJ45 Ethernet; USB: 2 front USB 3.0, 3 rearHDMI, S-video and composite video out; Ethernet (RJ45); USB: 2 front USB 3.0 and 3 rear; AC power input. HDMI carries no sound on R4, and sound on R4.5 when the external monitor supports HDMI audio. R1–R3 units have 4 front USB ports.Show allShow less
- Image storage
- About 345 GB for images on a 500 GB SSD; 776 MB Cine memory; on-board patient database
- Export and removable media
JPEG, JPEG2000, WMV, MPEG 4, AVI; USB stick 64 MB–4 GB, CD-R 700 MB, DVD-R 4.7 GBExport to JPEG, JPEG2000, WMV, MPEG 4 and AVI; DICOM storage compressed or uncompressed, single-frame or multiframe, with or without raw data; USB memory stick 64 MB to 4 GB for individual images and clips, CD-R 700 MB, DVD-R 4.7 GB; integrated DVD multi-drive optional.Show allShow less
- Peripherals and hardware options
B/W and color printers, wireless LAN, foot switch, video converter, barcode reader…Integrated digital B/W thermal printer, digital color thermal printer, HDMI and S-Video output for compatible devices, wireless LAN card, external USB printer connection, Power Assistant (battery or extended battery), programmable foot switch, universal video converter, barcode reader (regional clearance), LOGIQ P Apps over Bluetooth, Ethernet protection cable (regional clearance), physiological input panel with 2-lead ECG, rear cable hook, card reader mounting kit.Show allShow less
- Physiological input panel (option)
2-lead ECG, dual R-trigger, presettable R delay, adjustable gain, automatic heart ratePhysiological input panel (option): 2-lead ECG, dual R-trigger, pre-settable ECG R delay time and position, adjustable ECG gain, automatic heart rate display.Show allShow less
- LOGIQ P Apps (option)
Remote Control App and Camera App for Android, over BluetoothLOGIQ P Apps (option): Remote Control App and Camera App for Android over Bluetooth; the tablet tools are also listed as Remote Control App and Photo/Barcode Reader App. Remote Control operates the system from a tablet or phone with the LOGIQ Smart App; Photo Assistant photographs anatomy on an Android device and adds the photos to the report with the clinical images (release not stated).Show allShow less
- Security
- Privacy and Security (standard); SonoDefense cybersecurity and patient-data protection
Imaging & software
- Applications
Abdominal, obstetrical, gynecological, breast, small parts, musculoskeletal, vascular…Abdominal, obstetrical, gynecological, breast, small parts, musculoskeletal, vascular, urological, pediatric and neonatal, intraoperative (subject to regional regulatory clearance), cardiac, transcranial, endocavitary (transvaginal, transrectal), transesophageal.Show allShow less
- Imaging modes
B, Coded Harmonic, M, CFM, PDI, PW with high PRF, M-Color Flow, Anatomical M-Mode…Standard: B-Mode, Coded Harmonic Imaging, M-Mode, Color Flow Mode (CFM), Power Doppler Imaging (PDI), PW Doppler with high PRF, M-Color Flow Mode, Anatomical M-Mode and Curved Anatomical M-Mode; Anatomical M-Color Mode is also named. The R4 clearance lists B, M, PW Doppler, CW Doppler, Color Doppler, Color M Doppler, Power Doppler, Harmonic Imaging, Coded pulse, 3D/4D Imaging mode, Elastography, Shear Wave Elastography, Attenuation Imaging and combined modes.Show allShow less
- Optional modes
B-Flow, LOGIQView, contrast, CW, TVI, strain and shear wave elastography, 3D/4D, HDlive…B-Flow/B-Flow Color, Extended Field of View (LOGIQView), Coded Contrast Imaging, CW Doppler Mode, TVI Mode, Strain Elastography, Shear Wave Elastography, 3D/4D Volume Modes, HDlive, Offline Scanning Mode, B-Steer + and UGAP.Show allShow less
- Scanning methods
Electronic sector, convex, micro convex and linear; real-time 4D volume sweepElectronic sector, convex, micro convex and linear; real-time 4D volume sweep. Transducer types: sector phased array, convex array, microconvex array, linear array, matrix array, single CW (pencil) probes and volume (4D) probes.Show allShow less
- Imaging depth
- 0–48 cm displayed; field 0–1 cm minimum with zoom, 0–48 cm maximum (probe dependent)
- Maximum frame rate
- Up to 3229 F/s (R4)
- System dynamic range
- Greater than 400 dB, system-level composite (R4)
- System processing channels
- 386,469 (R4)
- Read zoom
- Maximum 20×
- Image rotation
- 0°, 90°, 180° or 270°
- Standard features (R4)
Automatic Optimization, CrossXBeam, SRI-HD, Coded Harmonic Imaging, Virtual Convex…Automatic Optimization (B-Mode contrast resolution low, medium or high, with Auto TGC); Coded Harmonic Imaging on all 2D and 4D probes; CrossXBeam Compounding with 3, 5, 7 or 9 angles; Speckle Reduction Imaging (SRI-HD); Virtual Convex on all linear and sector transducers; Fine Angle Steering; Doppler Assistant; Real-time Automatic Doppler Calculations; Raw Data Analysis; SonoRenderLive; OB Calculations; Fetal Trending; Multigestational Touch Control, with calculations for four gestations; IOTA (International Ovarian Tumor Analysis) LR2 worksheet, subject to regional regulatory clearance; MyPreset; MyTrainer+; Patient Information Database; Image Archive on integrated CD/DVD and SSD, the drive being optional; Email to MMS; Qpath; Tricefy; Vnav Import; InSite Capability.Show allShow less
- Coded Contrast (CEUS), option
U.S. use limited to focal liver lesions and left ventricle opacityCoded contrast imaging on the C1-5-RS, 3Sc-RS, IC9-RS, BE9CS-RS, 9L-RS, C1-6-D and C2-7-D; available in the U.S. only for characterizing focal liver lesions and left ventricle opacity. Includes Auto MI control and Time Intensity Curve (TIC) analysis; TIC motion tracking is also named. HRES CEUS is a further option; the HRes Contrast Upgrade was LOGIQ P9-only on R2 and R2.5.Show allShow less
- Elastography, option
Strain and Shear Wave (kPa, m/s); Elastography Quantification not cleared for the U.S.Strain Elastography on the C1-5-RS, L6-12-RS, 12L-RS, ML6-15-RS, L4-12t-RS, L3-12-RS, IC9-RS, E8CS-RS, BE9CS-RS, 9L-RS and C1-6-D. Shear Wave Elastography, subject to regional regulatory clearance, on the C1-5-RS, L3-12-RS, IC9-RS, ML6-15-RS, C1-6-D and 12L-RS, displaying kPa and m/s. Elastography with semi-quantification (Elastography Quantification) has not been cleared in the United States and is not available for promotion or sale there.Show allShow less
- UGAP, option
Ultrasound-Guided Attenuation Parameter for liver steatosis; R4 or laterUltrasound-Guided Attenuation Parameter, quantifying liver steatosis; R4 or later. On LOGIQ P9 R4.5 units with system software R4.5.7, recall Z-0157-2026 told users to stop using UGAP until GE HealthCare's correction is implemented.Show allShow less
- 3D/4D (option)
Real-time 4D and Static 3D; HDlive, STIC, VOCAL II, VCI Static, OmniView, SonoAVC…Real-time 4D, with Real-time 4D and Static 3D acquisition, Auto sweep, Betaview, the Scalpel 3D cut tool, VCI OmniView, and volume contrast imaging-static and tomographic ultrasound imaging as options within it; HDlive; STIC; Automated Volume Calculation – VOCAL II; VCI Static; OmniView; Tomographic ultrasound imaging; SonoAVC (R4 or later), with SonoAVC Renal also named; Advanced 3D (color data acquisition, automatic rendering, 3D landscape technology, 3D movie); Easy 3D; 3D reconstruction from a Cine sweep with rotation and planar translations.Show allShow less
- Cardiac options
Cardiac Strain (Cardiac AFI), AutoEF, Stress Echo, TVI with Q-Analysis, CW DopplerCardiac Strain (Cardiac AFI), combining three longitudinal views into a bulls-eye view of the left ventricle; AutoEF, semi-automatic global ejection fraction; Stress Echo, with exercise and pharmacological protocol templates, 8 default templates and wall motion scoring, plus Smart stress, which sets scanning parameters from the same projection at a previous stress level; Tissue Velocity Imaging (TVI) with Q-Analysis on the sector probes; CW Doppler on the 3Sc-RS, 6S-RS, 12S-RS, 6Tc-RS, P2D, P6D and P8D.Show allShow less
- Flow options
B-Flow/B-Flow Color with Hybrid B-Flow and HD Color; CF/PDI Quantification (FlowQA)B-Flow/B-Flow Color (option), including Hybrid B-Flow, B-Flow Color (BFC) and B-Flow High Definition Color (HD Color), on the C1-5-RS, 8C-RS, L6-12-RS, 12L-RS, 9L-RS, ML6-15-RS, L8-18i-RS, L4-12t-RS, L10-22-RS, L3-9i-RS, L3-12-RS, E8CS-RS, IC9-RS, BE9CS-RS, C1-6-D, C2-7-D and 10C-D; CF/PDI Quantification (FlowQA) option.Show allShow less
- OB options
- Measure Assist OB (BPD, HC, FL, AC); SonoNT/SonoIT, R4 or later
- Breast and thyroid options
Breast and Thyroid Productivity Packages; Koios Breast and Thyroid decision supportBreast Productivity Package; Thyroid Productivity Package; Measure Assist Breast, which contours and measures breast lesions automatically; Koios Breast Lesion Decision Support and Koios Thyroid Lesion Decision Support, each R4 or later and subject to regional regulatory clearance.Show allShow less
- Other software options
Scan Assistant, Start Assistant, Compare Assistant, Hepatic Assistant, Auto IMT…Scan Assistant; Start Assistant; Compare Assistant; Hepatic Assistant and Digital Expert, each subject to regional regulatory clearance; Auto IMT; B Steer+ on the C1-5-RS, 8C-RS, L6-12-RS, 12L-RS, 9L-RS, ML6-15-RS, L4-12t-RS, L3-12-RS, RAB2-6-RS, C1-6-D, C2-7-D and 10C-D; LOGIQView extended field of view in B-Mode; Report Writer; Software DVR; Software DVR Basic (R3 or later, no DVD title production); GT needle-position graphics overlaid on the image (R2.5 or R3).Show allShow less
- Other named features
Continuous Tissue Optimization, Measure Assistant, My Page, iLinq, Key macro, MPEGVue…Continuous Tissue Optimization (CTO) and Measure Assistant are named among the LOGIQ P9 XDclear's automated scanning tools; My Page is a personalized interface with user presets; Volume Navigation Import shows prior ultrasound, mammography, CT or MR images side by side with the exam's images; iLinq, Key macro, MPEGVue and TruAccess are named for R4. Release and licensing are not given for the first four.Show allShow less
- Revision and software
LOGIQ P9 releases R2, R2.5, R3, R4 and R4.5, after the original LOGIQ P9Model designations: LOGIQ P9 (5560938); LOGIQ P9 with Articulating Monitor Arm (5641037); LOGIQ P9 R2 with Articulating Monitor Arm (5724886); LOGIQ P9 R2.5 (5759915); LOGIQ P9 R3 (5794264); LOGIQ P9 R4 (5842859); LOGIQ P9 R4.5 (5877533). System software R4.5.7 runs on the LOGIQ P9 R4.5.Show allShow less
- Operating system
- Windows 10 Enterprise on R3, R4 and R4.5; embedded Windows 7 on R2 and R2.5
- Added in R4.5
Probe Health Test, Stepper Volume Measurement, EZ DICOM Viewer, UPS support, HDMI audio…Probe Health Test, which checks element integrity and function of compatible probes when one is connected or activated; Stepper Volume Measurement (STVOL); EZ DICOM Viewer; Koios Breast connectivity via DICOM; and minor improvements to Hepatic Assistant, week/day OB for SR, hide date and time, Quick Patient Change, UPS support, HDMI audio for an external monitor, DICOM Viewer SR storage and Digital Expert (licensing not stated).Show allShow less
Environment
- Operating environment
10–35 °C with 2D probes, 18–30 °C with 4D probes; humidity 10–80% non-condensingOperating 10–35 °C (50–95 °F) with a 2D probe and 18–30 °C (64.4–86 °F) with a 4D probe; storage and transport −10 to 50 °C (14–122 °F); operating humidity 10–80% non-condensing; pressure 700–1060 hPa.Show allShow less
- Cooling requirement
- 680 BTU/hr, excluding people, lights and other room equipment
- Acoustic noise
- 50 dB(A) maximum
Compliance
- FDA 510(k)
K214039 (2022-03-22, R4.5), K203114 (2021-01-08, R4), K181783, K163596, K161047, K143452K214039 (decided 2022-03-22; LOGIQ P10, LOGIQ P9 and LOGIQ P8, software version R4.5); K203114 (2021-01-08; the same three models, software version R4); K181783 (2018-09-20); K163596 (2017-02-10); K161047 (2016-05-05); K143452 (2015-01-29); the last four each clear the LOGIQ P9 with the LOGIQ P7. Class II, product code IYN.Show allShow less
- Safety conformance
ANSI/AAMI ES60601-1; CAN/CSA-C22.2 No. 60601-1:14; CE marked to 93/42/EECClassified to ANSI/AAMI ES60601-1 2005 R1 2012 by a nationally recognized test lab; certified to CSA CAN/CSA-C22.2 No. 60601-1:14; CE marked to Council Directive 93/42/EEC; further IEC/EN 60601 collateral and particular standards.Show allShow less
Languages
- Languages
English, French, German, Spanish, Italian, Portuguese, Russian, Greek, Swedish, Danish…English, French, German, Spanish, Italian, Portuguese, Russian, Greek, Swedish, Danish, Dutch, Finnish, Norwegian; Japanese and Chinese (messages only).Show allShow less
What to check when buying a used GE LOGIQ P9 XDclear
Reject a deformed, discolored or overheating battery
An internal transportation-mode battery on a LOGIQ P9 R3 leaked powdered electrolyte onto the power supply board, causing arcing, smoke and burn marks.
How: Check the battery for odor, heat, deformation or discoloration, and have any abnormal battery serviced before the system is used.
Inspect the power cord and inlet retainer
A cord with cuts, tire marks or exposed insulation, or an inlet that will not retain its plug, is an electrical fault to settle before purchase.
How: Look along the whole cord for cuts, loose hardware, tire marks and exposed insulation, check the power connectors for damage, and confirm the inlet connector retainer works.
Confirm the UGAP correction on R4.5.7 software
On LOGIQ P9 R4.5 units with system software R4.5.7, recall Z-0157-2026 found UGAP may display inaccurate liver steatosis values, and users were told to stop using UGAP until the correction is implemented.
How: Under Utility > About, affected software reads Software Version R4 with Software Revision 5.7, so read both and confirm GE HealthCare's correction has been applied.
Check the covers, shielding and air filters
Missing covers and hardware can cause interference while scanning, and a clogged filter can make the system overheat.
How: Confirm every EMI shield, internal cover, air-flow panel and screw is in place, and that the front and bottom air filters are fitted and clear.
Common questions about the GE LOGIQ P9 XDclear
Is the GE LOGIQ P9 XDclear FDA-cleared?
Yes. The LOGIQ P9 is FDA-cleared through 510(k) as a class II device, product code IYN. Its most recent clearance, K214039 for software version R4.5, was decided on March 22, 2022, and K203114 for software version R4 on January 8, 2021; both cover the LOGIQ P10, LOGIQ P9 and LOGIQ P8.
Earlier clearances for the LOGIQ P9, each shared with the LOGIQ P7, are K181783 (September 20, 2018), K163596 (February 10, 2017), K161047 (May 5, 2016) and K143452 (January 29, 2015).
What is the GE LOGIQ P9 XDclear used for?
It is a general imaging system, built for exams from triage to comprehensive studies. Its R4 clearance, K203114, indicates it for fetal and obstetric, abdominal, pediatric, small organ (breast, testes and thyroid), neonatal and adult cephalic, adult and pediatric cardiac, peripheral vascular, conventional and superficial musculoskeletal, urology including prostate, transrectal, transvaginal, transesophageal and intraoperative abdominal and vascular imaging, for use in a hospital or medical clinic.
How does the LOGIQ P9 XDclear compare with the LOGIQ P10 and LOGIQ P7?
The LOGIQ P10 is the highest configuration in the P Series, with every feature and probe the series offers; the LOGIQ P9 and LOGIQ P8 each offer a subset. On R4.5, the HDU monitor configuration is for the LOGIQ P10 only.
Against the LOGIQ P7, Coded Contrast Imaging was a LOGIQ P9-only option on the R1, R2 and R2.5 releases, and the HRes Contrast Upgrade was LOGIQ P9-only on R2 and R2.5.