The GE LOGIQ P9 XDclear is a general imaging ultrasound system, used from triage to comprehensive exams in obstetrical, gynecological, vascular, musculoskeletal and cardiac work. On R4 and R4.5 units it has a 23.8-inch monitor and 4 active probe ports, and weighs 67 kg at minimum load. The LOGIQ P10 is the highest P Series configuration, and the LOGIQ P9 and LOGIQ P8 each offer a subset of its features.

Released
2015first version launched
Probe ports
4 active3 RS + 1 DLP, R4/R4.5
Display
23.8-inchLCD monitor, R4/R4.5
Weight
67 kg148 lb, min. load, R4/R4.5

Compatible probes

Linear

  • 9L-RS
  • 12L-RS
  • L3-12-RS
  • L3-9i-RS Intraoperative, subject to regional clearance
  • L4-12t-RS
  • L6-12-RS
  • L8-18i-RS
  • L10-22-RS
  • ML6-15-RS Matrix array

Convex & microconvex

  • C1-5-RS
  • C1-6-D DLP connector; added with R4
  • C2-7-D DLP connector; added with R4
  • 8C-RS Microconvex
  • 10C-D Microconvex, DLP connector; added with R4
  • RAB2-6-RS 4D volume probe

Phased

  • 3Sc-RS Cardiac, abdomen, transcranial
  • 6S-RS Cardiac, pediatric, neonatal
  • 12S-RS Pediatric, neonatal
  • M5Sc-RS Added to the P Series with R4

Endocavity

  • E8C-RS Transvaginal, transrectal
  • E8CS-RS Transvaginal, transrectal
  • IC9-RS Transvaginal, transrectal
  • BE9CS-RS Transrectal
  • RIC5-9A-RS 4D volume; transvaginal, transrectal

Specialty

  • 6Tc-RS Transesophageal
  • P2D CW pencil
  • P6D CW pencil
  • P8D CW pencil

Specifications

Display
Main monitor
23.8-inch bezel-less LCD, LED backlight, on an articulating arm (R4, R4.5)
Touch screen
10.4-inch LCD touch screen
Main monitor (R1–R3)
21.5-inch color LCD; 10.4-inch LCD touch screen
Display modes
Full-size or split-screen live/stored display; 4×4 review; still and Cine thumbnails
Physical
Weight
67 kg (148 lb) at minimum load; 83 kg (183 lb) at maximum load (R4)Show all
Weight (R1–R3)
60 kg (133 lb)
Dimensions
H 1,345–1,595 mm with the monitor arm; W 545 mm (monitor); D 740 mm (rear handle)Show all
Dimensions (R1–R3)
Height 1,375–1,570 mm; width 530 mm monitor, 430 mm operator panel; depth 740 mm
Probe ports
4 active: 3 RS and 1 DLP; optional CW pencil probe port (R4, R4.5)
Probe ports (R1–R3)
3 active, 4th active port optional; optional CW pencil probe port
Controls
Full-size keyboard, swivel and height adjustable; digital TGC and A/N keyboardShow all
Console equipment
Integrated SSD, speakers, probe holders, front handle, probe light; optional DVD drive…Show all
Power & battery
Power
100–240 Vac, 50/60 Hz; maximum 500 VA with peripheralsShow all
Battery
Optional Power Assistant, Li-ion; extended battery: up to one hour of offline scanningShow all
Connectivity & options
Connectivity
Ethernet; DICOM 3.0 option; wireless LAN option; InSite ExC; LOGIQ P Apps (Bluetooth)Show all
Structured reporting
Public SR template; vascular and OB structured reporting; direct DICOM SR and XML export
Inputs and outputs
HDMI, S-video and composite video out; RJ45 Ethernet; USB: 2 front USB 3.0, 3 rearShow all
Image storage
About 345 GB for images on a 500 GB SSD; 776 MB Cine memory; on-board patient database
Export and removable media
JPEG, JPEG2000, WMV, MPEG 4, AVI; USB stick 64 MB–4 GB, CD-R 700 MB, DVD-R 4.7 GBShow all
Peripherals and hardware options
B/W and color printers, wireless LAN, foot switch, video converter, barcode reader…Show all
Physiological input panel (option)
2-lead ECG, dual R-trigger, presettable R delay, adjustable gain, automatic heart rateShow all
LOGIQ P Apps (option)
Remote Control App and Camera App for Android, over BluetoothShow all
Security
Privacy and Security (standard); SonoDefense cybersecurity and patient-data protection
Imaging & software
Applications
Abdominal, obstetrical, gynecological, breast, small parts, musculoskeletal, vascular…Show all
Imaging modes
B, Coded Harmonic, M, CFM, PDI, PW with high PRF, M-Color Flow, Anatomical M-Mode…Show all
Optional modes
B-Flow, LOGIQView, contrast, CW, TVI, strain and shear wave elastography, 3D/4D, HDlive…Show all
Scanning methods
Electronic sector, convex, micro convex and linear; real-time 4D volume sweepShow all
Imaging depth
0–48 cm displayed; field 0–1 cm minimum with zoom, 0–48 cm maximum (probe dependent)
Maximum frame rate
Up to 3229 F/s (R4)
System dynamic range
Greater than 400 dB, system-level composite (R4)
System processing channels
386,469 (R4)
Read zoom
Maximum 20×
Image rotation
0°, 90°, 180° or 270°
Standard features (R4)
Automatic Optimization, CrossXBeam, SRI-HD, Coded Harmonic Imaging, Virtual Convex…Show all
Coded Contrast (CEUS), option
U.S. use limited to focal liver lesions and left ventricle opacityShow all
Elastography, option
Strain and Shear Wave (kPa, m/s); Elastography Quantification not cleared for the U.S.Show all
UGAP, option
Ultrasound-Guided Attenuation Parameter for liver steatosis; R4 or laterShow all
3D/4D (option)
Real-time 4D and Static 3D; HDlive, STIC, VOCAL II, VCI Static, OmniView, SonoAVC…Show all
Cardiac options
Cardiac Strain (Cardiac AFI), AutoEF, Stress Echo, TVI with Q-Analysis, CW DopplerShow all
Flow options
B-Flow/B-Flow Color with Hybrid B-Flow and HD Color; CF/PDI Quantification (FlowQA)Show all
OB options
Measure Assist OB (BPD, HC, FL, AC); SonoNT/SonoIT, R4 or later
Breast and thyroid options
Breast and Thyroid Productivity Packages; Koios Breast and Thyroid decision supportShow all
Other software options
Scan Assistant, Start Assistant, Compare Assistant, Hepatic Assistant, Auto IMT…Show all
Other named features
Continuous Tissue Optimization, Measure Assistant, My Page, iLinq, Key macro, MPEGVue…Show all
Revision and software
LOGIQ P9 releases R2, R2.5, R3, R4 and R4.5, after the original LOGIQ P9Show all
Operating system
Windows 10 Enterprise on R3, R4 and R4.5; embedded Windows 7 on R2 and R2.5
Added in R4.5
Probe Health Test, Stepper Volume Measurement, EZ DICOM Viewer, UPS support, HDMI audio…Show all
Environment
Operating environment
10–35 °C with 2D probes, 18–30 °C with 4D probes; humidity 10–80% non-condensingShow all
Cooling requirement
680 BTU/hr, excluding people, lights and other room equipment
Acoustic noise
50 dB(A) maximum
Compliance
FDA 510(k)
K214039 (2022-03-22, R4.5), K203114 (2021-01-08, R4), K181783, K163596, K161047, K143452Show all
Safety conformance
ANSI/AAMI ES60601-1; CAN/CSA-C22.2 No. 60601-1:14; CE marked to 93/42/EECShow all
Languages
Languages
English, French, German, Spanish, Italian, Portuguese, Russian, Greek, Swedish, Danish…Show all

What to check when buying a used GE LOGIQ P9 XDclear

  1. Reject a deformed, discolored or overheating battery

    An internal transportation-mode battery on a LOGIQ P9 R3 leaked powdered electrolyte onto the power supply board, causing arcing, smoke and burn marks.

    How: Check the battery for odor, heat, deformation or discoloration, and have any abnormal battery serviced before the system is used.

  2. Inspect the power cord and inlet retainer

    A cord with cuts, tire marks or exposed insulation, or an inlet that will not retain its plug, is an electrical fault to settle before purchase.

    How: Look along the whole cord for cuts, loose hardware, tire marks and exposed insulation, check the power connectors for damage, and confirm the inlet connector retainer works.

  3. Confirm the UGAP correction on R4.5.7 software

    On LOGIQ P9 R4.5 units with system software R4.5.7, recall Z-0157-2026 found UGAP may display inaccurate liver steatosis values, and users were told to stop using UGAP until the correction is implemented.

    How: Under Utility > About, affected software reads Software Version R4 with Software Revision 5.7, so read both and confirm GE HealthCare's correction has been applied.

  4. Check the covers, shielding and air filters

    Missing covers and hardware can cause interference while scanning, and a clogged filter can make the system overheat.

    How: Confirm every EMI shield, internal cover, air-flow panel and screw is in place, and that the front and bottom air filters are fitted and clear.

Common questions about the GE LOGIQ P9 XDclear

Is the GE LOGIQ P9 XDclear FDA-cleared?

Yes. The LOGIQ P9 is FDA-cleared through 510(k) as a class II device, product code IYN. Its most recent clearance, K214039 for software version R4.5, was decided on March 22, 2022, and K203114 for software version R4 on January 8, 2021; both cover the LOGIQ P10, LOGIQ P9 and LOGIQ P8.

Earlier clearances for the LOGIQ P9, each shared with the LOGIQ P7, are K181783 (September 20, 2018), K163596 (February 10, 2017), K161047 (May 5, 2016) and K143452 (January 29, 2015).

What is the GE LOGIQ P9 XDclear used for?

It is a general imaging system, built for exams from triage to comprehensive studies. Its R4 clearance, K203114, indicates it for fetal and obstetric, abdominal, pediatric, small organ (breast, testes and thyroid), neonatal and adult cephalic, adult and pediatric cardiac, peripheral vascular, conventional and superficial musculoskeletal, urology including prostate, transrectal, transvaginal, transesophageal and intraoperative abdominal and vascular imaging, for use in a hospital or medical clinic.

How does the LOGIQ P9 XDclear compare with the LOGIQ P10 and LOGIQ P7?

The LOGIQ P10 is the highest configuration in the P Series, with every feature and probe the series offers; the LOGIQ P9 and LOGIQ P8 each offer a subset. On R4.5, the HDU monitor configuration is for the LOGIQ P10 only.

Against the LOGIQ P7, Coded Contrast Imaging was a LOGIQ P9-only option on the R1, R2 and R2.5 releases, and the HRes Contrast Upgrade was LOGIQ P9-only on R2 and R2.5.