The GE LOGIQ e X is the premium member of the LOGIQ e family, a portable system with AI-powered tools for point-of-care use. It serves MSK and sports medicine, rheumatology, anesthesiology, vascular, emergency, critical care and veterinary teams; its Nerveblox and MSK Go AI tools depend on configuration and region. Its sibling, the LOGIQ e S, provides essential imaging without the AI tools, Scan Assistant or AFI.
- Released
- 2026launched by GE
- Probe ports
- 2 or 3with the optional connector
- Display
- 15.6-inchLCD screen
Compatible probes
Linear
- 9L-RS · 3–9 MHz
- 12L-RS · 4.2–13 MHz
- L4-12t-RS · 4.2–13 MHz Four configurable buttons
- L4-20t-RS · 5–20 MHz XDclear; four configurable buttons
- L6-12-RS · 4–13 MHz
- L8-18i-RS · 6.7–18 MHz Hockey-stick
- L10-22-RS · 10–22 MHz
- ML6-15-RS · 5–15 MHz Active matrix
Convex & microconvex
- C1-5-RS · 2–5 MHz
- 4C-RS · 2–5 MHz
- C2-9-RS · 2.5–9 MHz XDclear
- 8C-RS · 4.2–11 MHz Microconvex
Phased
- 3Sc-RS · 1.7–4 MHz
- 6S-RS · 3–7 MHz
- 12S-RS · 4.1–12 MHz Pediatric cardiac
- M5Sc-RS · 1.8–4.5 MHz XDclear active matrix
Endocavity
- E8C-RS · 4.2–10 MHz Transrectal and transvaginal
- IC9-RS · 3.6–9 MHz Microconvex intercavity
Specialty
- 6Tc-RS · 3–8 MHz Transesophageal
- Vscan Air CL Wireless, dual-sided: curved 2.3–4.0 MHz and linear 4.5–8.5 MHz
- Vscan Air SL Wireless, dual-sided: sector 2.3–4.0 MHz and linear 4.5–8.5 MHz
Specifications
Display
- Display
- 15.6-inch LCD
- Resolution
- 1920 × 1080, color LCD
Physical
- Weight
- Approx. 4.5 kg (9.92 lb) with battery
- Probe ports
One direct connection on the console; optional connector takes two or three probesOne direct probe connection on the console; the optional two- or three-probe port connector connects two or three probes to the system and switches between them without disconnecting.Show allShow less
- Controls
- Trackball or trackpad; control panel with a redesigned keyboard
- Trackpad
- Scrolling, measurements, positioning, scan area and tilt; multi-touch gain and depth
- Carts
Optional: height-adjustable cart (830–1130 mm) or fixed-height Simple Cart (875 mm)Two optional carts. The height-adjustable primary LOGIQ e cart measures approx. 510 mm long × 510 mm wide, adjusts from 830 to 1130 mm high and takes an optional battery box of a charger box and 4 battery packs. The LOGIQ e Simple Cart measures approx. 555 mm long × 545 mm wide at a fixed 875 mm height, with no powered electrical components.Show allShow less
- Console models
- LOGIQ e X TB, TBU, TP and TPU consoles
- Color
- Black
- Cooling
- Low-noise fan
Power & battery
- Power
- Integrated battery or AC/DC power adapter
- Battery
One pack standard, optional second pack; cart battery box holds 4 packsIntegrated battery: one battery pack standard, with an optional second pack. The height-adjustable primary cart takes an optional battery box of a charger box and 4 battery packs.Show allShow less
- Battery scan time
- Up to 90 min on the console; up to 3.5 hours on the cart
Connectivity & options
- Network
- LAN and wireless LAN, wireless through a USB adapter
- Ports
- 3 × USB 3.0, HDMI, wired network
- DICOM
- NEMA PS 3.1–3.20, 2024e
- Connection Manager
- Setup wizard for network, remote devices, print flow, dataflow and local devices
- Verisound Fleet
Cloud management to view, back up and deploy configurations; not for diagnostic useCloud-based fleet management to remotely view, back up and deploy device configurations across locations; not available for all products or in all regions; not for diagnostic use.Show allShow less
- Verisound Collab
Real-time tele-mentoring; formerly Digital Expert Connect; not for diagnostic useReal-time tele-mentoring and collaboration on system use across a network; formerly named Digital Expert Connect; not available for all products or in all regions; not for diagnostic use.Show allShow less
- APP API
- Standard interface for integrating multiple software components
- Vscan Air connection
- Through a WiFi-Bluetooth USB adaptor, with the LOGIQ e X doing the processing
- Printer
- UP-D899MD printer accessory
Imaging & software
- Imaging modes
B, M, PW/CW Doppler, Color/Color M Doppler, Power Doppler, Harmonic Imaging, Coded PulseB, M, PW Doppler, CW Doppler, Color Doppler, Color M Doppler, Power Doppler, Harmonic Imaging and Coded Pulse, with the combined modes B/M, B/PWD, B/Color/PWD and B/Power/PWD.Show allShow less
- B-Flow
- Real-time blood flow imaging; angle-independent view of small vessels
- High-Res PDI
- On the ML6-15-RS probe
- Speckle Reduction Imaging HD (SRI-HD)
- Suppresses speckle while preserving tissue architecture
- AI tool availability
- Nerveblox and MSK Go are included depending on configuration and region
- Nerveblox
- Real-time AI labeling of key landmarks during peripheral nerve blocks
- MSK Go
- AI highlighting of musculoskeletal anatomy, for users qualified in MSK ultrasound
- Needle Recognition
- Designed to improve needle visibility in real time during guided procedures
- Scan Assistant
- Customizable program that guides the user step by step through exam protocols
- Auto EF
- Ejection fraction results
- Automated Function Imaging (AFI)
Longitudinal strain of the LV, RV and LA through the heart cycle; not in all regionsQuantitative analysis of longitudinal myocardial strain of the left ventricle, right ventricle and left atrium through the heart cycle; not available for all products in all regions.Show allShow less
- SonoBiometry
- Semi-automatic measurements of fetal head, abdomen and femur
- Voice Control
- Voice commands such as gain up, gain down, depth up and depth down
- MyPreset
- Saves frequently used scanning presets
- Revision and software
- R10 generation on Windows 11, updated from Windows 10
- Remote software updates
- Remote updates scheduled at user-chosen times; user-installed downloads need a GE account
- Processor
- Intel I5-125U
- Storage
- 512 GB SSD; 300 GB image storage
Environment
- Use environment
- Professional healthcare facilities only; hospital or medical clinic
- Handling environment
- 3 to 40 °C, 30–75% relative humidity, 70–106 kPa
- Storage environment
- -5 to 50 °C, 10–90% relative humidity, 70–106 kPa
Compliance
- FDA 510(k)
K260398 (2026-05-26), filed as LOGIQ e; Class II, 21 CFR 892.1550K260398, device name as filed LOGIQ e, found substantially equivalent on 2026-05-26 (received 2026-02-06); Class II, regulation 21 CFR 892.1550, product codes IYN (primary), IYO and ITX. The LOGIQ e X consoles are registered under K260398.Show allShow less
- CE marking
- CE marked
- Prescription use
- Rx only
- MRI safety
- MR Unsafe
- Manufactured in
- Wuxi, Jiangsu, China
Languages
- Voice Control languages
English, Chinese, Latin American Spanish, Swedish, German, Italian, French, Russian…English, Chinese, Latin American Spanish, Swedish, German, Italian, French, Russian, Greek, Brazilian Portuguese, Dutch and JapaneseShow allShow less
What to check when buying a used GE LOGIQ e X
Confirm the console label and Windows 11
LOGIQ e X consoles are registered under K260398, the clearance that moved the system from Windows 10 to Windows 11, while earlier LOGIQ e consoles sit under K232186.
How: Read the console label for an e X TB, TBU, TP or TPU model, noting that the regulatory name on the unit is LOGIQ e, and check that the system runs Windows 11.
Confirm each AI tool and option is enabled
Nerveblox, MSK Go, AFI and the Verisound tools depend on configuration and region, so any of them can be missing from a given unit.
How: Have every tool the seller lists demonstrated on the unit itself.
Count the battery packs and run on battery
One battery pack is standard and a second is optional, and the primary cart's optional battery box holds a charger box and four packs.
How: Count the packs in the console and in any cart battery box, then unplug the system and confirm it runs on battery.
Check for the multi-probe connector and test switching
The two- or three-probe port connector is an optional accessory, so a unit can arrive without it.
How: If it is included, connect two or three probes through it and switch between them without disconnecting any.
Common questions about the GE LOGIQ e X
Is the GE LOGIQ e X FDA-cleared?
Yes. It is FDA-cleared under 510(k) K260398, found substantially equivalent on May 26, 2026, as a Class II device under 21 CFR 892.1550 (product code IYN).
The clearance is filed under the name LOGIQ e, because LOGIQ e X is a marketing name for that product, and the LOGIQ e X consoles are registered under the same K260398.
What is the difference between the GE LOGIQ e X and LOGIQ e S?
The LOGIQ e X is the premium model of the LOGIQ e family, while the LOGIQ e S provides essential imaging. The AI-powered features, Scan Assistant and AFI are only on the LOGIQ e X, and both machines are marketing names for the same LOGIQ e product.
The L10-22-RS, L4-20t-RS, ML6-15-RS, 12S-RS, M5Sc-RS, 6Tc-RS and C2-9-RS probes and the Vscan Air CL and SL wireless probes are compatible with the LOGIQ e X but not the LOGIQ e S; the family's other probes are compatible with both.
The LOGIQ e X comes with a trackpad or a trackball, and the LOGIQ e S with a trackball.
What is the GE LOGIQ e X used for?
It is a general-purpose diagnostic ultrasound system for qualified, trained healthcare professionals, intended for use in a hospital or medical clinic.
Its cleared applications are ophthalmic, fetal/OB, abdominal (including GYN and urology), pediatric, small organ (breast, testes and thyroid), neonatal and adult cephalic, adult and pediatric cardiac, peripheral vascular, conventional and superficial musculoskeletal, transrectal, transvaginal, transesophageal, intraoperative (abdominal, thoracic and peripheral) and thoracic/pleural imaging for motion and fluid detection. It is also cleared for imaging guidance of interventional procedures such as nerve blocks and vascular access.
Can the GE LOGIQ e X be used for veterinary work?
Yes. Veterinary care is one of the LOGIQ e X's specialties, for teams working with equine, farm, companion, wild and exotic animals.
Its veterinary probe set adds the LK760-RS linear probe, which is for veterinary use only, and does not include the Vscan Air wireless probes.